Base
A 4-inch concrete base, concrete slabs, or timber deck, level and flat,
the size of the spa is recommended.
Power
A single-phase 240-volt power supply with 30mA R.C.D. (E.L.C.B.) fitted
at the fuse board.
An isolator minimum 2 metres from the water and a cable run to the back
wall of the tub with a 4-metre tail of cable loose, for our installers
to connect into the spa control panel. (Located behind the timber access
panel). If unsure contact a qualified electrician.
| MODEL |
Minimum Power |
Ideal Power |
| 2000 and 3000 series |
13 Amps |
20 Amps |
| 4000 series |
20 Amps |
30 Amps |
| Grand canyon |
30 Amps |
40 Amps |
| Tango Series |
| Tango 18 |
13 Amps |
20 Amps |
| Tango 18 turbo |
13 Amps |
20 Amps |
| Tango 26 turbo |
20 Amps |
30 Amps |
| Tango 42 turbo |
30 Amps |
40 Amps |
| Tango 42 Premier |
30 Amps |
40 Amps |
| Platinum Series |
| Platinum 20 |
13 Amps |
20 Amps |
| Platinum 40 |
20 Amps |
30 Amps |
| Platinum 60 |
30 Amps |
40 Amps |
| Platinum 60 Premier |
30 Amps |
40 Amps |
| |
The ideal power rating for cabling should be used if you
want to be able to run all the functions of the hottub at once. For example
in winter you may wish to run Jets, Pumps, Bubbler and Heater at the same
time.
Water
A garden hose is needed to fill the hot tub, preferably off the rising
main.
A garden hose is needed for emptying the hot tub, pushed on a spigot and
run to a drain.
|
Access
Sufficient access is required to the site. (Be aware of, doorways,
gates, corners, steps, drainpipes, trees, and branches, outside
taps, roof eaves, and steep slopes etc.)
Normally we use a dolly to move the spa on its side with 2 men .
So the height of your spa is now the width and the width is now
the height.
You may need to supply more manpower on the larger models.
If access to the site is not adequate, we can crane it over if necessary.
(Charged separately)
|

|
If you are unsure about any of the site preparation details
given here, call us or ask your electrician.
|